GeneAll

PRODUCTS

이미지
RUO

Biocontam-Zero Disinfection Solution for Water Bath in CO2 Incubators

Biocontam-Zero is a multi-purpose, ready-to-use concentrated solution for disinfecting the water baths in cell culture incubators. It has been proven to be an effective anti-microbial agent against bacteria, yeast, and fungi. It is encouraged to clean and disinfect the incubator systematically on a recommended basis every 14 days or at a minimum of once a month. Biocontam-Zero has been proven to be an extremely effective antimicrobial agent against recurring contamination.

SCALE / SIZE

Overview

Biocontam-Zero is a multi-purpose, ready-to-use concentrated solution for disinfecting the water baths in cell culture incubators.

It has been proven to be an effective anti-microbial agent against bacteria, yeast, and fungi.

It is encouraged to clean and disinfect the incubator systematically on a recommended basis every 14 days or at a minimum of once a month.

Biocontam-Zero has been proven to be an extremely effective antimicrobial agent against recurring contamination.

01

Preventative Treatment

  • Comprehensive antimicrobial spectrum
  • Effective on prevention of contamination by bacteria, yeast and fungi
02

Non-toxic Product

  • High-vitality
  • Non-toxic
  • Non-volatile
  • Anti-corrosive to stainless steel
03

Ready-to-use

  • Recommended dilution: 1:100 in sterile water.
  • Use 10 ml/L sterile water.
04

Applications

  • For disinfecting water baths of CO2 incubators

specifications

Technical Information

Features Biocontam-Zero
Recommended Use

The water in CO2 incubator should be replaced with sterile water every two to four weeks, by adding 10 ml of Biocontam-Zero per 1 L of water.

Storage Conditions -20~-10℃
Size 100 ml
Concentration 100X
Shelf Life 2 years (24 months)

Kit Contents

SolMate™ Biocontam-Zero Disinfection Solution (Cat. No. SM-B01-010)

  • SolMate™ Biocontam-Zero Disinfection Solution (100 ml)
  • Procedure

    1. Take a bottle from the proper storage conditions (-20°C) and read the label.

    2. Allow to thaw to room temperature prior to use.

    3. Ensure that the cap of the bottle is tight.

    4. Gently swirl the solution in the bottle.

    5. Wipe the outside of the bottle with a disinfectant solution such as 70% ethanol.

    6. Using aseptic/sterile technique under a laminar-flow culture hood, work according to

        established protocols.

    7. Recommended dilution: 1:100 in sterile water.

    Protocols